Thermbond Formula 12-L for FCCU High Erosion Service Applications

Industry: Refining & Petrochemical

Description of Equipment: New shop lined Regenerator Cyclone, Air Distributor, Slide Valve and Lampshade

Reason for using Thermbond: Superior erosion resistance for long-term performance.

Products Applied: Thermbond Formula 12-L

Method of Installation: Ramming and hand packing into hex-mesh

Equipment Used: Hobart Mixer, pneumatic rammer

Scope of Work: Thermbond Formula 12-L is typically installed 1 inch thick by hand packing into hexmesh to fill base of cells, then pneumatic ramming to complete installation. Surface is typically finished to top side of hexmesh with hard plastic block or soapstone.